Inquiry CartInquiry Cart
Home - blog

Exploring the Key Differences Between QSFP and QSFP28 in Modern Networking

December 24, 2024

As networking technologies develop and improve, it is important to keep childbearing practices in mind, as well as the scope for performance and scalability. In particular, two standards have emerged as significant components of modern data center infrastructures: the QSFP (Quad Small Form-factor Pluggable) and/or the QSFP28; however, many practitioners are still bewildered by the differences between the two. The authors of this article will attempt to clarify these technologies, Okpara et al. (this manual needs to show partial referencing). This includes a detailed SFP SFP28 and a more detailed comparison between QSFP and QSFP28. To put it another way, reinstate this concluding paragraph at the end of this paper. You’ll understand how to judge appropriately when to optimize or resource for speed, efficiency or even scalability for the foreseeable future.

What Transceiver Is a QSFP28?

Contents show

What Transceiver Is a QSFP28?

Criteria for Understanding the Form Factor of QSFP28

The latest achievement in optical networking, the QSFP28 (Quad Small Form-Factor Pluggable 28), received a major boost as it allows data transmission rates of up to 100 Gbps. Its small size enables it to be used in high-density situations in data centers and enterprise networks. Its external dimensions are roughly equal to 18.35 mm and 72.4 mm in width and length, respectively, making it possible to reduce the form factor of switches and routers as well as other network devices, making their use more space efficient.

The QSFP28 modems operate on different protocols and on different distances, including the 100GBASE-SR4 for connections covering short range and links with long reach connected by the LR4. They are designed in a way that allows the use of previous standards of QSFP, providing chances for expansion without catastrophic changes in the infrastructure (Commentator A, 2016). Furthermore, the fact that these components are hot-pluggable also enhances the smooth running and efficiency of the QSFP28. By employing four banks’ parallel optical lanes with a modulation speed of 25Gbps per lane, QSFP28 meets modern networking requirements satisfactorily.

Key Data Rate Capabilities of QSFP28

In summary, several key data rate capabilities supported by the QSFP28 enhance its usability for networking performance. These include the following requirements: 100 Gbps Transmission: This is achievable by combining four 25 Gbps lanes, making it easy to use 100 Gigabit Ethernet applications.

  • 25 Gbps Per Lane: Each optical lane works at a 25 Gbps rate, making it scalable for the next generation of network needs.
  • Lower Data Rates: According to support for QSFP+ usage, backward compatibility is maintained with a 40 Gbps Ethernet wireless adapter, thereby ensuring the applicability of the wireless adapter in a mixed network environment.

This functionality makes network migrations very easy while at the same time providing very high bandwidth and being cost-effective.

Compatibility Issues with QSFP28

One of the broad objectives that QSFP28 modules will accomplish is to interconnect advanced segments of the network. However, there are several compatibility issues that must be dealt with. First of all, compatibility is no issue for full-turn trunk QSFP28 layouts. However, full compatibility when interfacing with older cabling can become an issue. The use of differing data rates and power requirements in the older QSFP+ or QSFP modules may cause the modules to fail.

Furthermore, if QSFP28 modules are deployed into a legacy device, intermediate appliances might need to be replaced with new configurations. The hardware being used should be checked for port compatibility in terms of their specifications, and appropriate firmware should be combined with the hardware to prevent any integration failures. These possible issues can be effectively alleviated with good design and network infrastructure compliance.

What is the Key Difference Between QSFP and QSFP28?

What is the Key Difference Between QSFP and QSFP28?

Utilizing Correct Firmware Versions

Though utilizing QSFP28 modules, it must be noted that the user upgrading firmware is necessary. They have considered addressing issues, compatibility of modules, and development of new features to strengthen firmware against future issues. Check if the corresponding files, such as update files, match the hardware model and version of the device being updated. There are suggested procedures and protocols on firmware installation, these involve obtaining the update from an official site, checking the update within the network management area, then deploying the update itself. Regularly scheduled updates should be employed ubiquitously so that defects and limitations of the network environment are minimized.

What’s the Difference Between QSFP vs QSFP28 Connectors?

Both QSFP (Quad Small Form-factor Pluggable) and QSFP28 are modules intended for transceiver use but have different dimensions, speeds, and capacities. The maximum data transfer rate corresponds to 40G Ethernet or InfiniBand. A four-channel bidirectional module designed for High-speed usage, with a target data transfer rate of 40Gbps. No such limitations are imposed on QSFP28 as it is engineered for high performance and is targeted to have a bandwidth of 100Gbps for 100G Ethernet.

Overall, the geometries of the QSFP and the QSFP28 connectors appear similar, allowing backward compatibility in many instances. However, the design of the internal structure of the QSFP28 modules incorporates more sophisticated techniques to retrieve bandwidth usage more efficiently. The QSFP28-type interface has become the norm in most data centers and high-performance computing systems, which require greater throughput.

Comparing Data Center Applications

The crucial aspect of choosing between QSFP and QSFP28 modules for the data center applications is to consider first the bandwidth capacity, then the bandwidth efficiency of the modules, as well as the evolution capacity. QSFP modules are ideal for use in older, built-in or ready environments that do not support connections above 40Gbps. On the other hand, the development of new architecture owing to the efficient processing of the signals came up with the quad small form-factor pluggable (QSFP28) ports, which are superior in modern systems where transmission speed is crucial with a transfer rate of 100Gbps. The more common use of the QSFP28-type interface is on active telecommunication networks deployed within cloud computing programs. To enhance the modular system’s performance and efficiency, the bandwidth specifications necessary to support the existing operational requirements and the bandwidth capability expansion required when purposes change should be established in advance.

What is the Role of SFP in the Context of QSFP28?

What is the Role of SFP in the Context of QSFP28?

Engaging the SFP28 vs QSFP28 Discussion

Regarding role allocation, SFP28 and QSFP28 modules are used for different functions depending on the network’s tailoring. SFP28 operates on a single lane, not exceeding data rates of 25Gbps. It has been deployed for connections of low-bandwidth applications such as servers and storage systems in high-traffic environments.

In contrast, QSFP28 has four lanes, allowing it to operate at a bandwidth ceiling of 100Gbps. This makes it highly rated as the best for switching high- and core networks with aggregation. The data rates per port are high, so scalability is highly flexible in a data center or cloud connection.

When a user decides on SFP28 over QSFP28, several factors should be considered: the data rate needed, the density of ports required, and the room for future expansion. SFP28 will be ideal for deployment in scenarios where cost is the primary target compared to lower bandwidth. However, QSFP28 will be ideal in high-capacity networking technologies with high and flexible throughput requirements.

The Advancements the 25G SFP28 Brings Along the Network Configurations

The SFP28 25G, in a way, is the game changer in the landscape of network configurations as it serves more than one purpose and helps deploy networks across various scenarios.  It especially helps monitor 25 Gbps servers and Top Of Rack (ToR) Switch interconnections, helping to use optimized bandwidth cheaply. Based on the application, the 25G SFP26 module helps in technological advancement. It provides extended reach options, such as up to 100 m over OM4 multimode fiber or even higher than single-mode fibers.

Moreover, this configuration is fully compatible with the existing 10G SFP+ systems, eliminating the worry about plugging in the older systems and allowing room for future high-bandwidth requirements. Given the low power contour and complexity of the design, the 25G SFP28 is the perfect solution in high-density data center cases. The module coverage’s importance in reducing network bottlenecks and high-speed interconnects prominently highlights the 25G SFP26’s role in the post-networking generations’ transition.

What are the Uses of QSFP28 Transceivers?

What are the Uses of QSFP28 Transceivers?

Implementing 100G Standards within Ethernet Networks

The 100G QSFP28 optical transceivers are mainly seen in high-speed ethernet networks in response to the rising need for high-speed data transfers. They are used in numerous cases, such as data center interconnect links, high-performance computing cluster systems, and companies’ core networks. Such transceivers open up a whole new range of possibilities by increasing the network’s available bandwidth. Enabling faster data handover and communication, they incorporate a small form factor. They are compatible with switches, routers, and various other networking devices making them suitable for enhancing the networking capabilities of enormous cloud structures or departments of numerous organizations.

Infiniband Use Cases for QSFP28

I can confidently state that Qsfp28 connectors are likely to be the crown’s jewels regarding the expansion of high-speed connections on InfiniBand networks. Their applications are quite broad in the areas that require low latency and very high throughput, such as high-performance computing HPC or machine learning applications. These transceivers allow for effective data transfers between servers, storage, and compute nodes, thus helping complex computing clusters operate. Due to their high-performance level, they are ideal for expanding the InfiniBand applications in research and industry activities, especially using QSFP28 connectors.

What is the difference between QSFP-DD and QSFP28?

What is the difference between QSFP-DD and QSFP28?

Evaluating the Mtach Technology for QSFP-DD Transceivers

The QSFP-DD (Quad Small Form-factor Pluggable Double Density) transceiver technology was formulated to increase data rates and scalability over QSFP28. In this regard, the QSFP-DD enhances the structural bandwidth of its transmission by supporting up to 400Gbps through 8 lanes. Its application seems ideal for today’s dense data centers, cloud, and AI workloads. This transceiver’s backward compatibility with the older QSFP28 facilitates its incorporation into legacies and paves an avenue for escalating future networks. QSFP-DD is designed to support dense port configuration of networking devices and equipment, hence reducing the space and power needed per bit of data transferred, which is important for economic purposes, particularly for large-scale infrastructures.

Implication for Modern Applications and Scenarios

As noted earlier, a single QSFP28 connection can support a data bandwidth rate of up to 100 Gbps. Such speeds are made possible through a design incorporating four lanes at 25 Gbps each. Of course, this limit is acceptable only for moderate bandwidth requirements, such as networking on an enterprise level and even to an extent, smaller data centers. A more important development structurally is that QSFP-DD expands that capability to as much as 400 Gbps albeit through eight lanes operating at 50 Gbps each. This technological advancement makes QSFP-DD suitable for even the most demanding of environments, including hyperscale data centers and data processing applications. The bulk of this capability is, however, useful when one wants to consider the requirements that modern networks have and the traffic thereof because QSFP-DD encompasses high data rates and, within those high data rates, high scalability.

Ensuring Longevity with QSFP-DD and QSFP28

These options, QSFP-DD and QSFP28, provide alternative options for ensuring a strong network backbone based on the deployment needs. The case of QSFP28 is best suited for organizations with more of a deployment-centered approach in building their networks where 100GB PS links are adequate to provide sufficient connectivity more cost-effectively. For those enterprises that, in the long run, plan to add on to their capacity, investing in QSFP-DD is a much better bet as it delivers on throughput levels of 400gbps and so will be able to support developing high-definition use cases with many applications and lots of data. The reverse compatibility to the QSFP28 provides further parameters for decision, easing the shift when the need arises. This way, when properly utilized, the case of adopting QSFP-DD facilitates companies’ remaining competitive within their market while justifying the costs of deploying new technologies.

Frequently Asked Questions (FAQs)

Q: What are the two modules’ main differences between the QSFP and the QSFP28?

A: The main differences between the QSFP and the QSFP28 modules lie in the portability and compatibility. A kQSFP has a maximum data rate of 40G, while a kQSFP28 has a maximum data rate of 100. The kQSFP28 enhances the kQSFP as it has a higher capacity. Furthermore, the kQSFP28 has 4x25G lanes while the kQSFP has 4x10G lanes. The greater the k QSFP to kQSFP28 enhancement stage, the greater the number of these optical modules’ lanes per port.

Q: Can a QSFP28 transceivers operate in a 40G QSFP port?

A: Generally, kQSFP28 modules generally work back on kQSFP ports because they are backward compatible. This means if I have a kQSFP28 optical transceiver, I can still use it in a kQSFP port, but it will have a maximum output of 40G instead of 100G. However, it is recommended to consult the specific module and switch parameters and specifications to determine compatibility.

Q: What is the difference between QSFP and standard SFP modules?

A: Essentially, the SFP concept forms the basis of a QSFP module. A QSFP interconnect device can replace four “normal” SFP interconnects in a single port. This change results in higher port density and lower power consumption per gigabit. However, the form factors and electrical interfaces are different; thus, QSFP cannot be inserted into an SFP port.

Q: What are the main characteristics of optical transceivers of type QSFP28?

A: Optical transceivers of type QSFP28 have several interesting features, such as: 1. They can support 100G data rates and protocols 2. Ports implemented with 40g QSFP are utilized as well 3. Its design is high-density, including four channels in one module. 4. Power consumption is significantly lowered compared to using four independent SFP28 transceivers. 5. There is support for a wide range of transmission media, including short-reach transmission, long-reach transmission, and active optical cables.

Q: What is the difference between QSFP, QSFP28 and SFP28 transceivers?

A: The SFP28 transceiver is a single-channel module categorized for 25G data rates, whereas QSFP and QSFP28 categorize 4-channel modules. SFP28 is simply a progression of the SFP+ standard, whereas QSFP28 is a progression of the QSFP standard. The three main differences consist of: 1. Form factor: SFP28 – smaller than QSFP/QSFP28 2. Channel count: SFP28 has a single channel, and QSFP/QSFP28 has four channels. 3. Total bandwidth: SFP28 working bandwidth reaches 25G, QSFP working bandwidth reaches 40G, while QSFP28 working bandwidth reaches 100G.

Q: Do SFP ports accept the insertion of QSFP or QSFP28 modules?

A: No, there are significant variances in the form factors and electrical interfaces, so inserting SFP ports directly into QSFP and QSFP28 modules is impossible. Yet some other switches include QSFP ports, which allow SFP optics to be installed through attachments of special adapters or breakout cables. However, not all switches with QSFP ports can work with SFP optics, so it is best to research your switch specifications before purchasing them.

Q: Why is there a need to change QSFP28 to 4 separate SFP28 transceivers?

A: Utilizing a single QSFP28 module in place of 4 SFP28 transceivers has several benefits, including 1. Higher port density, therefore saving space in network devices 2. Overall power consumption is less than 3. Easier communication with cables since fewer attachments are required 4. An economical approach in dealing with many high bandwidths needs 5—ability to work at 40G or 100G based on network requirements.

Q: When did the transition from QSFP to QSFP28 occur, and how did it affect modern networking growth?

A: The change from QSFP to QSFP28 improved modern networking in many ways. For instance, 1—deployment of up to 100G band with the same appearance 2. Provided means to upgrade the network specifications slowly as the earlier installment remains supported 3, accelerating the demand for improved performance for data center and enterprise networks 4. Advanced the development of 400G networks using the QSFP-DD, the following generation of the QSFP28 5. Developed an affordable means to provide a high-speed and high-density network.

Reference Sources

  1. Integrated Silicon Photonics Transmitter in 400GBASE-DR4 QSFP-DD Transceiver
    • Authors: Xingyu Zhang et al.
    • Publication Date: 2021-06-01
    • Key Findings: This paper presents the design and characterization of a 4-channel silicon photonics transmitter for 400Gbps DR4 data-center applications. The QSFP-DD transceiver module demonstrated reliable performance in real-time operation across a temperature range of 0 to 70 °C. The study emphasizes the importance of silicon photonics in enhancing the data transmission capabilities of QSFP modules.
    • Methodology: The authors conducted design and performance evaluations of the silicon photonics transmitter, focusing on its integration into the QSFP-DD form factor and its operational reliability under varying conditions(Zhang et al., 2021, pp. 1–3).
  2. A record energy-efficient QSFP ELS for co-packaged optics demonstrates the advancements in optical module technology.
    • Authors: K. Nagai et al.
    • Publication Date: 2023
    • Key Findings: This study demonstrates an uncooled pigtailed-QSFP ELS (External Laser Source) employing an 8-channel CWDM (Coarse Wavelength Division Multiplexing) TOSA (Transmitter Optical Sub-Assembly) for co-packaged optics. The ELS achieves a high power conversion efficiency of 14.3% at a housing temperature of 55 ºC, showcasing advancements in energy efficiency for QSFP modules.
    • Methodology: The authors performed experimental evaluations to assess the energy efficiency and operational performance of the QSFP ELS under practical conditions(Nagai et al., 2023).
  3. 1800 km 16QAM transmission with a 400G QSFP-DD coherent pluggable
    • Authors: W. Sande et al.
    • Publication Date: 2023
    • Key Findings: This paper reports on real-time long-haul transmission using a 400G digital subcarrier-multiplexed QSFP-DD coherent pluggable in a live production network, achieving a record post-FEC (Forward Error Correction) error-free reach of 1800 km with 400G-16QAM. This demonstrates the capabilities of QSFP-DD technology in high-performance networking.
    • Methodology: The authors conducted field tests to evaluate the transmission performance of the QSFP-DD module over long distances, analyzing the error rates and overall network performance(Sande et al., 2023).

Key Differences Between QSFP and QSFP28

While the papers do not provide a direct comparison, here are some general differences based on standard specifications for these technologies:

  • Data Rate:
    • QSFP: Typically supports data rates of up to 40 Gbps (4×10 Gbps).
    • QSFP28: Designed to support data rates of up to 100 Gbps (4×25 Gbps), making it suitable for higher bandwidth applications.
  • Form Factor:
    • Both QSFP and QSFP28 share a similar physical form factor, allowing for backward compatibility in many cases. However, QSFP28 modules are optimized for higher performance and efficiency.
  • Applications:
    • QSFP: Commonly used in data center interconnects and high-speed networking applications.
    • QSFP28: Primarily used in high-performance computing, data centers, and telecommunications, particularly for 100G Ethernet applications.