{"id":8121,"date":"2024-12-24T09:48:30","date_gmt":"2024-12-24T01:48:30","guid":{"rendered":"https:\/\/ascentoptics.com\/blog\/?p=8121"},"modified":"2026-07-03T18:02:39","modified_gmt":"2026-07-03T10:02:39","slug":"what-is-the-difference-between-sfp28-and-qsfp28","status":"publish","type":"post","link":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/","title":{"rendered":"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases"},"content":{"rendered":"<p>SFP28 and QSFP28 are two widely used optical transceiver form factors in modern Ethernet networks. Both support high-speed data transmission, hot-swappable installation, and flexible fiber or copper media options. However, they are designed for different bandwidth requirements and network architectures.<\/p>\n<p>In simple terms, SFP28 is a single-lane 25G form factor, while QSFP28 combines four 25G lanes to deliver 100G aggregate bandwidth. This makes SFP28 a strong choice for 25G server access and top-of-rack connections, while QSFP28 is more suitable for high-density 100G uplinks, spine-leaf networks, cloud data centers, and breakout applications.<\/p>\n<p>This guide compares SFP28 and <a href=\"https:\/\/ascentoptics.com\/blog\/qsfp28-transceiver\/\" target=\"_blank\" rel=\"noopener\">QSFP28<\/a> transceivers in terms of speed, lane architecture, port density, reach, connectors, power consumption, cost, compatibility, and deployment scenarios so you can choose the right module for your network.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2 class=\"font-bold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\">What Are SFP28 And QSFP28 Together?<\/h2>\n<p>&nbsp;<\/p>\n<p>SFP28 stands for Small Form-factor Pluggable 28. It is designed for 25 Gigabit Ethernet and typically carries one 25Gbps electrical lane. QSFP28 stands for Quad Small Form-factor Pluggable 28. It uses four 25Gbps lanes in one module to support 100 Gigabit Ethernet.<\/p>\n<p>Although both transceiver types use similar high-speed signaling concepts, they are not interchangeable form factors. SFP28 ports are mainly used for 25G access links, while QSFP28 ports are used for 100G aggregation, uplinks, and 4x25G breakout connections when the switch supports breakout mode.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Quick Comparison: SFP28 vs QSFP28<\/strong><\/h3>\n<table style=\"height: 967px;\" width=\"926\">\n<tbody>\n<tr>\n<td width=\"210\"><strong>Parameter<\/strong><\/td>\n<td width=\"318\"><strong>SFP28<\/strong><\/td>\n<td width=\"318\"><strong>QSFP28<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Form factor<\/strong><\/td>\n<td width=\"318\">Small Form-factor Pluggable 28<\/td>\n<td width=\"318\">Quad Small Form-factor Pluggable 28<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Lane architecture<\/strong><\/td>\n<td width=\"318\">1 x 25Gbps lane<\/td>\n<td width=\"318\">4 x 25Gbps lanes<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Typical Ethernet rate<\/strong><\/td>\n<td width=\"318\">25GbE<\/td>\n<td width=\"318\">100GbE or 4 x 25GbE breakout<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Best network role<\/strong><\/td>\n<td width=\"318\">Server access, edge links, top-of-rack connections<\/td>\n<td width=\"318\">Switch uplinks, aggregation, spine-leaf networks, high-density 100G links<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Common optical connectors<\/strong><\/td>\n<td width=\"318\">LC duplex for most optical modules<\/td>\n<td width=\"318\">MPO\/MTP for SR4\/PSM4; LC duplex for CWDM4, LR4, ER4<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Common copper options<\/strong><\/td>\n<td width=\"318\">25G SFP28 DAC<\/td>\n<td width=\"318\">100G QSFP28 DAC or 4 x 25G breakout DAC<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Typical reach examples<\/strong><\/td>\n<td width=\"318\">SR up to 70m OM3 \/ 100m OM4; LR up to 10km<\/td>\n<td width=\"318\">SR4 up to 70m OM3 \/ 100m OM4; CWDM4 up to 2km; LR4 up to 10km; ER4 up to 40km<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Power profile<\/strong><\/td>\n<td width=\"318\">Usually lower per port; varies by reach and vendor<\/td>\n<td width=\"318\">Higher per module, but efficient per 100G link<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Breakout support<\/strong><\/td>\n<td width=\"318\">Not applicable as a single-lane form factor<\/td>\n<td width=\"318\">Often supports 4 x 25G breakout, depending on switch and cable\/module type<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Primary standards<\/strong><\/td>\n<td width=\"318\">25GbE, commonly associated with IEEE 802.3by<\/td>\n<td width=\"318\">100GbE, commonly associated with IEEE 802.3ba and IEEE 802.3bm; some variants follow MSAs<\/td>\n<\/tr>\n<tr>\n<td width=\"210\"><strong>Main advantage<\/strong><\/td>\n<td width=\"318\">Cost-effective 25G connectivity with lower power and simple deployment<\/td>\n<td width=\"318\">Higher bandwidth, better uplink density, and flexible 100G-to-25G breakout<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12727 aligncenter\" src=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/SFP28-vs-QSFP28-at-a-Glance.png\" alt=\"SFP28 vs QSFP28 at a Glance\" width=\"609\" height=\"457\" srcset=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/SFP28-vs-QSFP28-at-a-Glance.png 1448w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/SFP28-vs-QSFP28-at-a-Glance-267x200.png 267w\" sizes=\"auto, (max-width: 609px) 100vw, 609px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>SFP28 Overview: 25G Single-Lane Connectivity<\/strong><\/h2>\n<p><a href=\"https:\/\/ascentoptics.com\/25g-sfp28\/\" target=\"_blank\" rel=\"noopener\">SFP28 transceivers<\/a> are built for 25G Ethernet. They use a compact form factor that is similar in size to SFP+ but supports a higher data rate. In many data centers, SFP28 is used to upgrade 10G server access links to 25G without moving directly to 100G at the server edge.<\/p>\n<ul>\n<li><strong>Data rate: <\/strong>25Gbps per port.<\/li>\n<li><strong>Typical use: <\/strong>Server-to-switch links, top-of-rack access, enterprise aggregation, storage networks, and edge deployments.<\/li>\n<li><strong>Media options: <\/strong>Optical transceivers, DAC cables, and AOC cables.<\/li>\n<li><strong>Connectors: <\/strong>Most SFP28 optical modules use LC duplex connectors; DAC and AOC cables use integrated SFP28 ends.<\/li>\n<li><strong>Reach: <\/strong>Short-reach multimode links for data center rooms and long-reach single-mode links for building or campus connections.<\/li>\n<li><strong>Power and cost: <\/strong>Usually lower than QSFP28 on a per-module basis, making it attractive for many 25G access links.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>QSFP28 Overview: 100G Four-Lane Connectivity<\/strong><\/h2>\n<p><a href=\"https:\/\/ascentoptics.com\/100g-qsfp28\/\" target=\"_blank\" rel=\"noopener\">QSFP28 transceivers<\/a> provide 100G aggregate bandwidth by combining four 25Gbps lanes in one module. This makes QSFP28 a common choice for data center uplinks, switch-to-switch connections, and high-capacity aggregation layers.<\/p>\n<ul>\n<li><strong>Data rate: <\/strong>100Gbps aggregate bandwidth, typically built from four 25Gbps lanes.<\/li>\n<li><strong>Typical use: <\/strong>Leaf-spine uplinks, core switching, cloud networks, data center interconnect, and high-performance computing environments.<\/li>\n<li><strong>Breakout capability: <\/strong>Many QSFP28 ports can be split into four 25G lanes using a QSFP28-to-4xSFP28 DAC, AOC, or optical breakout solution, if the switch supports breakout configuration.<\/li>\n<li><strong>Connectors: <\/strong>SR4 and PSM4 usually use MPO\/MTP connectors, while CWDM4, LR4, and ER4 usually use LC duplex connectors.<\/li>\n<li><strong>Reach: <\/strong>Available from short-reach multimode links to long-reach single-mode links for campus, metro, and data center interconnect applications.<\/li>\n<li><strong>Port efficiency: <\/strong>A single QSFP28 port can replace four independent 25G lanes at the uplink layer, helping reduce cabling complexity and improve rack-level bandwidth density.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12728 aligncenter\" src=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Single-Lane-vs-Four-Lane-Architecture.png\" alt=\"Single-Lane vs Four-Lane Architecture\" width=\"634\" height=\"476\" srcset=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Single-Lane-vs-Four-Lane-Architecture.png 1448w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Single-Lane-vs-Four-Lane-Architecture-267x200.png 267w\" sizes=\"auto, (max-width: 634px) 100vw, 634px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Key Differences Between SFP28 and QSFP28<\/strong><\/h2>\n<h3><strong>1. Data Rate and Lane Architecture<\/strong><\/h3>\n<p>The most important difference is bandwidth. SFP28 carries one 25Gbps lane, while QSFP28 carries four 25Gbps lanes for a total of 100Gbps. If your device needs one 25G connection, SFP28 is usually the direct match. If you need 100G uplinks or 4x25G breakout, QSFP28 is the better fit.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>2. Port Density and Switch Design<\/strong><\/h3>\n<p>SFP28 is optimized for high-density 25G access ports. QSFP28 is optimized for high-density 100G uplinks. A typical leaf switch may use many SFP28 ports for servers and several QSFP28 ports for uplinks to spine switches. This design balances access density and uplink bandwidth.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>3. Connector Type and Fiber Cabling<\/strong><\/h3>\n<p>SFP28 optical modules commonly use LC duplex connectors. QSFP28 connector choice depends on the module type. 100G SR4 and PSM4 usually use MPO\/MTP multi-fiber connectors, while 100G CWDM4, LR4, and ER4 usually use LC duplex connectors. Choosing the wrong connector or fiber type is one of the most common deployment mistakes.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>4. Transmission Distance<\/strong><\/h3>\n<p>Both SFP28 and QSFP28 support short-reach and long-reach options. For example, 25G SFP28 SR and 100G QSFP28 SR4 are used for short multimode fiber links inside data centers. SFP28 LR, QSFP28 CWDM4, QSFP28 LR4, and QSFP28 ER4 are used for longer single-mode fiber links.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>5. Power Consumption and Thermal Planning<\/strong><\/h3>\n<p>SFP28 modules generally consume less power per port than QSFP28 modules because they support one lane instead of four. However, QSFP28 can be more efficient at the uplink level because one 100G module can replace four 25G links. Always check the module datasheet, especially for long-reach and high-temperature deployments.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>6. Cost and Cost per Gigabit<\/strong><\/h3>\n<p>SFP28 usually has a lower unit price, which makes it cost-effective for 25G server connections. QSFP28 costs more per module, but it may reduce the total number of ports, cables, and switch slots needed for 100G aggregation. The best choice depends on whether you are optimizing for module price, total bandwidth, port count, or long-term scalability.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Transmission Distance and Module Types<\/strong><\/h2>\n<p>The right module type depends on the distance, fiber type, connector type, and switch compatibility. The table below lists common examples used in 25G and 100G Ethernet networks.<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Module Type<\/strong><\/td>\n<td width=\"78\"><strong>Rate<\/strong><\/td>\n<td width=\"108\"><strong>Media<\/strong><\/td>\n<td width=\"120\"><strong>Connector<\/strong><\/td>\n<td width=\"240\"><strong>Typical Reach<\/strong><\/td>\n<td width=\"174\"><strong>Typical Use<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/25g-sfp28-sr.html\" target=\"_blank\" rel=\"noopener\"><strong>25G SFP28 SR<\/strong><\/a><\/td>\n<td width=\"78\">25G<\/td>\n<td width=\"108\">MMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 70m over OM3 or 100m over OM4<\/td>\n<td width=\"174\">Short data center links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/25g-sfp28-lr-10km.html\" target=\"_blank\" rel=\"noopener\"><strong>25G SFP28 LR<\/strong><\/a><\/td>\n<td width=\"78\">25G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 10km<\/td>\n<td width=\"174\">Campus or building links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/25g-sfp28-er-40km.html\" target=\"_blank\" rel=\"noopener\"><strong>25G SFP28 ER<\/strong><\/a><\/td>\n<td width=\"78\">25G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 40km<\/td>\n<td width=\"174\">Longer single-mode links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/25g-sfp28-dac\/\" target=\"_blank\" rel=\"noopener\"><strong>25G SFP28 DAC<\/strong><\/a><\/td>\n<td width=\"78\">25G<\/td>\n<td width=\"108\">Copper twinax<\/td>\n<td width=\"120\">Integrated SFP28 ends<\/td>\n<td width=\"240\">Typically up to 5m<\/td>\n<td width=\"174\">In-rack server connections<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/100g-qsfp28-sr4.html\" target=\"_blank\" rel=\"noopener\"><strong>100G QSFP28 SR4<\/strong><\/a><\/td>\n<td width=\"78\">100G<\/td>\n<td width=\"108\">MMF<\/td>\n<td width=\"120\">MPO\/MTP<\/td>\n<td width=\"240\">Up to 70m over OM3 or 100m over OM4<\/td>\n<td width=\"174\">Short data center uplinks<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/100g-qsfp28-psm.html\" target=\"_blank\" rel=\"noopener\"><strong>100G QSFP28 PSM4<\/strong><\/a><\/td>\n<td width=\"78\">100G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">MPO\/MTP<\/td>\n<td width=\"240\">Commonly used for parallel single-mode links, often up to 500m or 2km depending on specification<\/td>\n<td width=\"174\">Parallel SMF data center links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/100g-qsfp28-ir4-cwdm4.html\" target=\"_blank\" rel=\"noopener\"><strong>100G QSFP28 CWDM4<\/strong><\/a><\/td>\n<td width=\"78\">100G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 2km<\/td>\n<td width=\"174\">Data center interconnect and campus links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/100g-qsfp28-lr4-lwdm4.html\" target=\"_blank\" rel=\"noopener\"><strong>100G QSFP28 LR4<\/strong><\/a><\/td>\n<td width=\"78\">100G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 10km<\/td>\n<td width=\"174\">Longer aggregation links<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><a href=\"https:\/\/ascentoptics.com\/product\/100g-qsfp28-er4-lwdm4.html\" target=\"_blank\" rel=\"noopener\"><strong>100G QSFP28 ER4<\/strong><\/a><\/td>\n<td width=\"78\">100G<\/td>\n<td width=\"108\">SMF<\/td>\n<td width=\"120\">LC duplex<\/td>\n<td width=\"240\">Up to 40km<\/td>\n<td width=\"174\">Metro or long campus connections<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>100G QSFP28 DAC\/AOC<\/strong><\/td>\n<td width=\"78\">100G or 4 x 25G<\/td>\n<td width=\"108\">Copper or active optical cable<\/td>\n<td width=\"120\">Integrated QSFP28 ends; breakout variants use SFP28 ends<\/td>\n<td width=\"240\">DAC typically short in-rack links; AOC supports longer rack-to-rack links<\/td>\n<td width=\"174\">High-density, flexible cabling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12732 aligncenter\" src=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/QSFP28-Breakout-to-4-\u00d7-SFP28.png\" alt=\"QSFP28 Breakout to 4 \u00d7 SFP28\" width=\"645\" height=\"484\" srcset=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/QSFP28-Breakout-to-4-\u00d7-SFP28.png 1448w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/QSFP28-Breakout-to-4-\u00d7-SFP28-267x200.png 267w\" sizes=\"auto, (max-width: 645px) 100vw, 645px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>When Should You Choose SFP28?<\/strong><\/h2>\n<ul>\n<li>Choose SFP28 when your network needs 25G access links rather than 100G uplinks.<\/li>\n<li>Use SFP28 for server-to-switch connectivity in top-of-rack designs.<\/li>\n<li>Choose SFP28 when you want a lower-cost upgrade path from 10G to 25G.<\/li>\n<li>Use SFP28 when port-level granularity matters and each device only needs one 25G connection.<\/li>\n<li>Choose SFP28 DAC cables for short in-rack copper connections when distance and cable flexibility allow it.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>When Should You Choose QSFP28?<\/strong><\/h2>\n<ul>\n<li>Choose QSFP28 when you need 100G bandwidth between switches, routers, servers, or storage systems.<\/li>\n<li>Use QSFP28 for leaf-spine uplinks, aggregation layers, cloud data centers, and high-performance computing networks.<\/li>\n<li>Choose QSFP28 breakout when one 100G port needs to connect to four 25G SFP28 devices.<\/li>\n<li>Use QSFP28 CWDM4, LR4, or ER4 when you need single-mode 100G links over longer distances.<\/li>\n<li>Choose QSFP28 when reducing the number of uplink ports and cables is more important than the lower unit cost of SFP28.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Compatibility Notes: What to Check Before Buying<\/strong><\/h2>\n<p>Physical fit is not the same as electrical or software compatibility. Before purchasing SFP28 or QSFP28 modules, confirm the following requirements:<\/p>\n<ul>\n<li><strong>Port support: <\/strong>The switch or NIC must support the target speed and form factor. A QSFP28 module cannot be inserted into an SFP28 cage.<\/li>\n<li><strong>Breakout mode: <\/strong>For QSFP28-to-4xSFP28 connections, the switch port must support breakout configuration, and the correct cable or optical breakout module must be used.<\/li>\n<li><strong>FEC requirements: <\/strong>Some 25G and 100G links require Forward Error Correction settings to match on both sides.<\/li>\n<li><strong>Fiber type: <\/strong>Do not mix multimode optics with single-mode fiber, or MPO\/MTP parallel optics with LC duplex links.<\/li>\n<li><strong>Coding and vendor compatibility: <\/strong>Some switches require compatible transceiver coding. Verify the module part number against the switch vendor or module supplier.<\/li>\n<li><strong>Power budget and temperature: <\/strong>Long-reach modules may consume more power and generate more heat. Check switch port power limits and airflow.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>Common Deployment Scenarios<\/b><\/strong><\/h2>\n<table style=\"height: 486px;\" width=\"989\">\n<tbody>\n<tr>\n<td width=\"192\"><strong>Scenario<\/strong><\/td>\n<td width=\"282\"><strong>Recommended Option<\/strong><\/td>\n<td width=\"372\"><strong>Why It Fits<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"192\"><strong>25G server access<\/strong><\/td>\n<td width=\"282\">SFP28 SR, SFP28 LR, SFP28 DAC, or SFP28 AOC<\/td>\n<td width=\"372\">Common in enterprise and cloud data center top-of-rack designs.<\/td>\n<\/tr>\n<tr>\n<td width=\"192\"><strong>100G switch uplink<\/strong><\/td>\n<td width=\"282\">QSFP28 SR4, CWDM4, LR4, ER4, DAC, or AOC<\/td>\n<td width=\"372\">Used between leaf and spine switches or between aggregation layers.<\/td>\n<\/tr>\n<tr>\n<td width=\"192\"><strong>100G to 4x25G breakout<\/strong><\/td>\n<td width=\"282\">QSFP28-to-4xSFP28 DAC\/AOC or optical breakout solution<\/td>\n<td width=\"372\">Useful when connecting one 100G switch port to four 25G devices.<\/td>\n<\/tr>\n<tr>\n<td width=\"192\"><strong>Short in-rack cabling<\/strong><\/td>\n<td width=\"282\">SFP28 DAC or QSFP28 DAC<\/td>\n<td width=\"372\">Low cost and low latency, but limited reach and cable flexibility.<\/td>\n<\/tr>\n<tr>\n<td width=\"192\"><strong>Longer campus or data center interconnect<\/strong><\/td>\n<td width=\"282\">SFP28 LR\/ER or QSFP28 CWDM4\/LR4\/ER4<\/td>\n<td width=\"372\">Requires single-mode fiber and correct optical budget planning.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12730 aligncenter\" src=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28.png\" alt=\"Typical Network Applications of SFP28 and QSFP28\" width=\"633\" height=\"475\" srcset=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28.png 1448w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28-267x200.png 267w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28-1024x768.png 1024w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28-133x100.png 133w, https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/Typical-Network-Applications-of-SFP28-and-QSFP28-768x576.png 768w\" sizes=\"auto, (max-width: 633px) 100vw, 633px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>SFP28 vs QSFP28: Which One Is Better?<\/strong><\/h2>\n<p>Neither form factor is universally better. SFP28 is better for cost-effective 25G access links, while QSFP28 is better for 100G aggregation, uplinks, and high-density data center architectures. The correct choice depends on network speed, switch port type, fiber infrastructure, reach, breakout requirements, power budget, and upgrade plans.<\/p>\n<p>A practical design often uses both: SFP28 for server access and QSFP28 for uplinks. This combination provides efficient 25G edge connectivity while preserving high-capacity 100G paths between switches.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2 class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\">Frequently Asked Questions (FAQs)<\/h2>\n<h3>Q: SFP28 Transceiver and QSFP28 transceiver have a distinct difference, what is it?<\/h3>\n<p>A: What sets SFP28 transceivers apart is that they are limited to 25 Gbps rates, while QSFT28 transceivers enable 100 Gbps. This enables it to supersede four standard sPf ports. In simpler terms SFP28 transceivers are an upgrade when compared to the sFP series. Nevertheless, QSFP28 has the capability of supporting four 25 Gbps channels which deciphers the reason as to why it\u2019s an ideal choice for managing large amounts of data.<\/p>\n<h3>Q: Comparing SFP28 with QSFP28 transceivers, how do regulations differ for each of the transceivers?<\/h3>\n<p>A: The fuselages in an SFP28 transceiver are distinctly different which influences its efficiency to comply with the 25Gbps standard compliance requirements, on the other hand 100 Gbps standard compliance for QSFP28 are time based requirements. In essence both transceivers need to be compliant with the ultimate Network Interface Device in order to be used in multi purpose networks.<\/p>\n<h3>Q: Are SFP28 ports QSFP28 transceivers compatible?<\/h3>\n<p>A: Unfortunately due to the dissimilarities in the model and the amount of channels they can support they\u2019re not able to be used directly with each other. However this does not mean that there are no other options available, there are breakout cables for SFP28 ports which can be connected with multiple other SFPs.<\/p>\n<h3>Q: In comparison to the conventional SFP transceivers, what are the advantages offered Concerning the use of SFP28 Transceivers?<\/h3>\n<p>A: As confinement of data rates around 25 Gbps and above, SFP28 transceivers offer stronger performance compared to their predecessors. Consequently, this allow for their use in contemporary data center applications which require higher reliability as well as speed, while also ensuring full backward capacity within existing SFP ports.<\/p>\n<h3>Q: How does the evolution of QSFP transceivers impact network design?<\/h3>\n<p>A \u2018 Computers are beginning to take off with the development of networks, and QSFP transceivers improve their performance . This is enabled by the QSFP28 which supports 100Gbps data rates that are more efficient to a network infrastructure, decreasing the need for excessive cabling and equipment that can be expensive in comparison to an SFP solution.<\/p>\n<h3>Q: SFP28 optical transceiver has compatibility limitations?<\/h3>\n<p>A: Then considering the SFP28 optical transceiver, the aim is for most SFP28 ports, but other network connecting devices should ideally already support the 25Gbps speed. An SFP28 is backward compatible with SFP ports, but doing so would simply limit SFP28\u2019s potential to 1G SFP speeds.<\/p>\n<h3>Q: How does the cost of QSFP28 transceivers compare to SFP28 transceivers?<\/h3>\n<p>A: Particularly, QSFP28 transceivers are costlier than SFP28 transceivers largely becuase of the fact that they function at the decadal range of 100Gbps. The difference in the pricing for each of the transceivers originates from the fact that SFP28 capabilities and flexibility differs from that of a QSFP28 transceiver.<\/p>\n<h3>Q: What role does the QSFP28 optical transceiver play in modern networks?<\/h3>\n<p>A: The transceiver itself facilitates efficient transmission of mega data and with this ease, the process to transfer data at a rate of 100 gigabits per second becomes process capable for enterprise networks, data centers, and telecommunications headsets with ease. In other words, the transceiver is now the backbone of a network connection.<\/p>\n<h3>Q: Why might an organization choose to use SFP28 transceivers over QSFP28 transceivers?<\/h3>\n<p>A: An Integer state unit that does not possess the capability of delivering a connection that is above the speed range of 25 Gbps can opt for SFP28 transceivers. In contrast to its horrendously expensive counterpart, QSFP28, SFP28 transceivers allow set within a plateau of world movement to upgrade existing infrastructure at a much more reasonable price.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/en.wikipedia.org\/wiki\/Small_Form-factor_Pluggable\" target=\"_blank\" rel=\"dofollow\" ><span class=\"mw-page-title-main\">Small Form-factor Pluggable<\/span><\/a><\/p>\n<p><a href=\"https:\/\/en.wikipedia.org\/wiki\/100_Gigabit_Ethernet\" target=\"_blank\" rel=\"dofollow\" ><span class=\"mw-page-title-main\">100 Gigabit Ethernet<\/span><\/a><\/p>\n<div id=\"p-lang-btn\" class=\"vector-dropdown mw-portlet mw-portlet-lang\"><a href=\"https:\/\/ascentoptics.com\/blog\/everything-you-need-to-know-about-100g-qsfp28-transceivers\/\" target=\"_blank\"><span class=\"mw-page-title-main\">Everything You Need to Know About 100G QSFP28 Transceivers<\/span><\/a><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<style>\r\n.lwrp.link-whisper-related-posts{\r\n            \r\n            margin-top: 22px;\nmargin-bottom: 12px;\r\n        }\r\n        .lwrp .lwrp-title{\r\n            \r\n            \r\n        }.lwrp .lwrp-description{\r\n            \r\n            \r\n\r\n        }\r\n        .lwrp .lwrp-list-container{\r\n        }\r\n        .lwrp .lwrp-list-multi-container{\r\n            display: flex;\r\n        }\r\n        .lwrp .lwrp-list-double{\r\n            width: 48%;\r\n        }\r\n        .lwrp .lwrp-list-triple{\r\n            width: 32%;\r\n        }\r\n        .lwrp .lwrp-list-row-container{\r\n            display: flex;\r\n            justify-content: space-between;\r\n        }\r\n        .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n            width: calc(50% - 20px);\r\n        }\r\n        .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n            \r\n            margin-top: 11px;\nmargin-right: 16px;\nmargin-bottom: 15px;\nmargin-left: 9px;\r\n        }\r\n        .lwrp .lwrp-list-item img{\r\n            max-width: 100%;\r\n            height: auto;\r\n            object-fit: cover;\r\n            aspect-ratio: 1 \/ 1;\r\n        }\r\n        .lwrp .lwrp-list-item.lwrp-empty-list-item{\r\n            background: initial !important;\r\n        }\r\n        .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n        .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n            \r\n            \r\n            \r\n            \r\n        }@media screen and (max-width: 480px) {\r\n            .lwrp.link-whisper-related-posts{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-title{\r\n                \r\n                \r\n            }.lwrp .lwrp-description{\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-multi-container{\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-multi-container ul.lwrp-list{\r\n                margin-top: 0px;\r\n                margin-bottom: 0px;\r\n                padding-top: 0px;\r\n                padding-bottom: 0px;\r\n            }\r\n            .lwrp .lwrp-list-double,\r\n            .lwrp .lwrp-list-triple{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-row-container{\r\n                justify-content: initial;\r\n                flex-direction: column;\r\n            }\r\n            .lwrp .lwrp-list-row-container .lwrp-list-item{\r\n                width: 100%;\r\n            }\r\n            .lwrp .lwrp-list-item:not(.lwrp-no-posts-message-item){\r\n                \r\n                \r\n            }\r\n            .lwrp .lwrp-list-item .lwrp-list-link .lwrp-list-link-title-text,\r\n            .lwrp .lwrp-list-item .lwrp-list-no-posts-message{\r\n                \r\n                \r\n                \r\n                \r\n            };\r\n        }<\/style>\r\n<div id=\"link-whisper-related-posts-widget\" class=\"link-whisper-related-posts lwrp\">\r\n            <h3 class=\"lwrp-title\">Related Posts<\/h3>    \r\n        <div class=\"lwrp-list-container\">\r\n                                <div class=\"lwrp-list lwrp-list-row-container lwrp-list-double-row\">\r\n                <div class=\"lwrp-list-item\"><a href=\"https:\/\/ascentoptics.com\/blog\/100g-qsfp28-transceivers-types-applications-and-selection-guide\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">100G QSFP28 Transceivers: Types, Applications and Selection Guide<\/span><\/a><\/div>                <\/div>\r\n                            <div class=\"lwrp-list lwrp-list-row-container lwrp-list-double-row\">\r\n                <div class=\"lwrp-list-item\"><a href=\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-qsfp-and-qsfp28\/\" class=\"lwrp-list-link\"><span class=\"lwrp-list-link-title-text\">Exploring the Key Differences Between QSFP and QSFP28 in Modern Networking<\/span><\/a><\/div>                <\/div>\r\n                <\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>SFP28 and QSFP28 are two widely used optical transceiver form factors in modern Ethernet networks. Both support high-speed data transmission, hot-swappable installation, and flexible fiber or copper media options. However, they are designed for different bandwidth requirements and network architectures. In simple terms, SFP28 is a single-lane 25G form factor, while QSFP28 combines four 25G [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12726,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_wpscp_schedule_draft_date":"","_wpscp_schedule_republish_date":"","_wpscppro_advance_schedule":false,"_wpscppro_advance_schedule_date":"","_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_selected_social_profile":null},"categories":[1],"tags":[],"class_list":["post-8121","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.7 (Yoast SEO v22.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog<\/title>\n<meta name=\"description\" content=\"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog\" \/>\n<meta property=\"og:description\" content=\"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/\" \/>\n<meta property=\"og:site_name\" content=\"AscentOptics Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100092593417940\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-24T01:48:30+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-03T10:02:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"AscentOptics\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@AscentOptics\" \/>\n<meta name=\"twitter:site\" content=\"@AscentOptics\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AscentOptics\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/\",\"url\":\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/\",\"name\":\"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog\",\"isPartOf\":{\"@id\":\"https:\/\/ascentoptics.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png\",\"datePublished\":\"2024-12-24T01:48:30+00:00\",\"dateModified\":\"2026-07-03T10:02:39+00:00\",\"author\":{\"@id\":\"https:\/\/ascentoptics.com\/blog\/#\/schema\/person\/5a02970945bd03dd06d7fa2cf09b62bc\"},\"description\":\"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage\",\"url\":\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png\",\"contentUrl\":\"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png\",\"width\":1672,\"height\":941,\"caption\":\"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ascentoptics.com\/blog\/#website\",\"url\":\"https:\/\/ascentoptics.com\/blog\/\",\"name\":\"AscentOptics Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ascentoptics.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/ascentoptics.com\/blog\/#\/schema\/person\/5a02970945bd03dd06d7fa2cf09b62bc\",\"name\":\"AscentOptics\",\"sameAs\":[\"https:\/\/ascentoptics.com\/blog\"],\"url\":\"https:\/\/ascentoptics.com\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog","description":"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/","og_locale":"en_US","og_type":"article","og_title":"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog","og_description":"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.","og_url":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/","og_site_name":"AscentOptics Blog","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100092593417940","article_published_time":"2024-12-24T01:48:30+00:00","article_modified_time":"2026-07-03T10:02:39+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png","type":"image\/png"}],"author":"AscentOptics","twitter_card":"summary_large_image","twitter_creator":"@AscentOptics","twitter_site":"@AscentOptics","twitter_misc":{"Written by":"AscentOptics","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/","url":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/","name":"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases - AscentOptics Blog","isPartOf":{"@id":"https:\/\/ascentoptics.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage"},"image":{"@id":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage"},"thumbnailUrl":"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png","datePublished":"2024-12-24T01:48:30+00:00","dateModified":"2026-07-03T10:02:39+00:00","author":{"@id":"https:\/\/ascentoptics.com\/blog\/#\/schema\/person\/5a02970945bd03dd06d7fa2cf09b62bc"},"description":"Discover the key differences between SFP28 and QSFP28 transceivers. Learn about their regulations, compatibility, and applications in optical networks.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ascentoptics.com\/blog\/what-is-the-difference-between-sfp28-and-qsfp28\/#primaryimage","url":"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png","contentUrl":"https:\/\/ascentoptics.com\/blog\/wp-content\/uploads\/2024\/12\/139.png","width":1672,"height":941,"caption":"SFP28 vs QSFP28: Key Differences, Specifications, and Use Cases"},{"@type":"WebSite","@id":"https:\/\/ascentoptics.com\/blog\/#website","url":"https:\/\/ascentoptics.com\/blog\/","name":"AscentOptics Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ascentoptics.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/ascentoptics.com\/blog\/#\/schema\/person\/5a02970945bd03dd06d7fa2cf09b62bc","name":"AscentOptics","sameAs":["https:\/\/ascentoptics.com\/blog"],"url":"https:\/\/ascentoptics.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/posts\/8121","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/comments?post=8121"}],"version-history":[{"count":7,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/posts\/8121\/revisions"}],"predecessor-version":[{"id":12734,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/posts\/8121\/revisions\/12734"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/media\/12726"}],"wp:attachment":[{"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/media?parent=8121"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/categories?post=8121"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ascentoptics.com\/blog\/wp-json\/wp\/v2\/tags?post=8121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}